General

  • Standard horizontal full/medium heat recovery (boiler) unit for gas engine plants
  • For CHP (district heating hot-water) applications or generation of steam
  • High efficiency
  • Vibration-considered robust construction
  • Compact shop-assembled module -design with small footprint and low operational weight
  • Designed with water tubes and gilled tubes
  • Easy and fast installation
  • Below design data is typical data with standard execution
  • Special solutions considered on case-by-case basis


Design data

 

Diesel engine output: No limits, depending on engine
Diesel engine fuel type: Light oil, Natural gas, Heavy fuel oil
Exhaust gas flow: No limits
Exhaust gas temperature: < 500 ºC
Operating pressure: Standard 5 - 30 bar(g)
Steam temperature: Standard up to 400 ºC
Circulation: Forced
Pinch point: Standard 15 - 20 ºC, min. 5 ºC limited by feasibility only




For inquiries, please contact sales@aalborg-industries.fi

 