Go to frontpage


Marine Boilers
& Heat Exchangers
 

Alfa Laval Aalborg XW-TG

________________________________________________________________________________________

 

General

 

  • Forced circulation exhaust gas boiler/economizer
  • Water tube boiler with gilled tubes for exhaust gas heat recovery
  • Robust, well-proven construction, able to withstand vibrations and exhaust gas pulsation
  • Heating surface composition which ensures the required output from the most compact unit
  • Efficient, well-proven cleaning system with steam or air soot blowers
  • Superheater and preheater as an option

 

Design data

 

Steam capacity: 15 - 34.0 t/h
Heat capacity: 0.1 - 21 MW
Steam pressure: 18 - 24 bar(g)

 

 

Description

 

The Aalborg XW-TG (formerly MISSION™ XW-TG) is a water tube, forced circulation exhaust gas boiler/economizer. It is specially designed for heat recovery from diesel engine exhaust gas or turbo-generator but the basic design suits numerous applications.

 

The heating surface is made of double gilled tubes with a spacing which minimizes soot build-up. It is supplied with an efficient cleaning system with steam or compressed air sootblowers.

 

A design with single gilled tubes is also available.

The economizer can be supplied with a dividing wall system for connection of several exhaust gas sources to one boiler.

 

The Aalborg XW-TG may be used in conjunction with an oil-fired auxiliary boiler or a separate steam drum, in both cases acting as a steam/water separator.

 

This solution is a part of Alfa Laval Aalborg's green technology initiatives.

Content on this page requires a newer version of Adobe Flash Player.

Get Adobe Flash player

 

 

DATA SHEET series
© Aalborg Industries 2008 (Design data are subject to change without prior notice).

 