General
- Forced circulation exhaust gas boiler/economizer
- Water tube boiler with gilled tubes for exhaust gas heat recovery
- Robust, well-proven construction, able to withstand vibrations and exhaust gas pulsation
- heating surface composition which ensures the required output from the most compact unit
- Efficient, well-proven cleaning system with steam or air soot blowers
- Superheater and preheater as an option
Design data
| Steam capacity: |
0.2 - 17 t/h |
| Heat capacity: |
0.1 - 21 MW |
| Steam pressure: |
12 - 22 bar(g) |
Description
The MISSION™ XW is a water tube, forced circulation exhaust gas boiler/economizer. It is specially designed for heat recovery from diesel engine exhaust gas but the basic design suits numerous applications.
The heating surface is made of double gilled tubes with a spacing which minimizes soot build-up. It is supplied with an efficient cleaning system with steam or compressed air sootblowers.
A design with single gilled tubes is also available.
The economizer can be supplied with a dividing wall system for connection of several exhaust gas sources to one boiler.
The MISSION™ XW may be used in conjunction with an oil-fired auxiliary boiler or a separate steam drum, in both cases acting as a steam/water separator.
In connection with a thorough revision/ standardization of Aalborg Industries' marine boiler product range, the exhaust gas economizer previously referred to as AV-6N has been renamed to MISSION™ XW. The abbreviation refers to eXhaust gas Water tube boiler.
|